El par de columnas GCE Zen-O (RS-00513) es el conjunto de cribas moleculares (sieve beds) OEM diseñado exclusivamente para el concentrador portátil de oxígeno Zen-O de GCE. Con el tiempo, las columnas de zeolita se degradan y deben reemplazarse para mantener la pureza del oxígeno y el flujo terapéutico. Este componente de reemplazo permite que proveedores de oxígeno domiciliario o usuarios experimentados realicen el cambio en menos de 5 minutos con herramientas básicas, minimizando el tiempo de inactividad para pacientes que dependen de oxigenoterapia continua.
Key Features
- OEM replacement: manufactured to GCE specifications for the Zen-O POC
- Field-replaceable: swap in under 5 minutes with a 2.5mm Allen key and 7mm nut driver
- Restores oxygen purity: essential when the device shows decreased flow or low-purity alarms
- Sold as a pair: includes both column modules for a complete replacement
- Not compatible with Zen-O Lite: use RS-00616 for the Zen-O Lite model
Specifications
| Spec | Value |
|---|---|
| Part Number | RS-00513 |
| Compatible Device | GCE Zen-O Portable Oxygen Concentrator |
| Installation Time | Under 5 minutes |
| Tools Required | 2.5mm Allen key, 7mm nut driver |
| Replacement Interval | Every 12-18 months, or when low-purity or service alarms appear |
| Condition | New (OEM) |
| Sold As | Pair (both column modules included) |
What’s Included
- 1 x GCE Zen-O Column Pair — sieve bed assembly (RS-00513), both modules
Zen-O concentrator unit sold separately. Not compatible with Zen-O Lite (RS-00616 required for Zen-O Lite).
When to Replace
Replace the column pair when your Zen-O displays reduced oxygen output, activates a low-purity alarm, or shows a service alarm code indicating high sieve-bed hours. Typical replacement interval is every 12-18 months depending on daily usage. A leak check must be performed after replacement to confirm proper installation.
Warranty
1-year warranty by American Oxygen. Sold and supported by our bilingual team in Doral, Florida.
FAQ
Is RS-00513 compatible with the Zen-O Lite?
No. The Zen-O Lite uses a different column pair (RS-00616). RS-00513 is exclusively for the standard Zen-O POC.
Do I need a technician to install it?
No. The Zen-O column pair is designed for field replacement by home oxygen providers or trained users with standard hand tools. A leak check is required after installation.
What are the signs I need to replace my columns?
Decreased oxygen output, low-purity error alarms, unusual concentrator noise, or a high sieve-bed hour count in the device diagnostics.
Does this come as a pair?
Yes — RS-00513 includes both sieve bed column modules, covering a complete replacement of the full column assembly.