Inogen Output Filters – 10 Pack (RP-410)
Protect the delivery side of your Inogen concentrator with the Inogen One G4 Output Filters – 10 Pack (RP-410). These tiny, critical filters sit directly under the cannula barb and catch fine particulates right before oxygen reaches your tubing—supporting consistent oxygen purity and reducing nuisance alarms.
Designed for easy, at-home maintenance, this 10-pack covers up to 10 months of routine replacements when changed monthly. Ideal for users and caregivers who want to keep therapy reliable with a simple, repeatable routine.
What’s in the Box
-
10 × Inogen RP-410 Output Filters (individually packed)
-
Quick install guidance
Need the removal tool or barb? See Related Accessories below.
Specifications (at a glance)
| Feature | Detail |
|---|---|
| SKU / MPN | RP-410 |
| Function | Output particulate filtration (under the cannula barb) |
| Compatibility | Inogen One G4 |
| Washable/Reusable | No – dispose after use |
| Typical Interval | Monthly (or sooner in dusty environments) |
| Tools | Use RP-404 output filter tool to remove/reseat the barb safely |
| Install Time | ~2 minutes (DIY) |
| Condition | New, non-sterile accessory |
Compatibility & Parts Notes
-
Devices: Inogen One G4
-
Cannula barbs (sold separately):
-
G4 barb: often labeled SP-711
-
G5 barb: often labeled RP-505
-
-
Tool: Use the RP-404 (output filter tool/spanner) to lift the barb cleanly.
-
If you are unsure of your model or barb part, check the label on your device or contact our support team.
Replacement Schedule (Quick Guide)
| Situation | Action | When |
|---|---|---|
| Routine maintenance | Replace one RP-410 | Every month |
| Dusty/pet environment | Replace more frequently | Every 2–3 weeks |
| After travel | Inspect & replace if discolored | Upon return |
| Signs of restriction/hiss at outlet | Replace filter and re-seat barb | As needed |
Do not operate the device without an output filter installed.
Installation – Step by Step (Safe Method)
-
Power off the concentrator.
-
Using the RP-404 tool, gently remove the cannula barb (avoid pliers or twisting that can mar the outlet).
-
Pull the used RP-410 straight out; do not wash or reuse.
-
Insert a new RP-410 fully into the outlet port.
-
Re-seat the barb straight in until snug (hand pressure only).
-
Power on and confirm normal flow (no hissing or looseness).
Tip: Add a calendar reminder for the first day of each month.
Why This 10-Pack?
-
Consistent output quality: Fresh filters help keep oxygen delivery clean.
-
Prevents avoidable issues: Reduces chance of outlet restriction and alarms.
-
Budget & time friendly: One order covers months of maintenance.
-
DIY simple: No clinic visit, no calibration, 2-minute swap.
FAQs
1) Are RP-410 filters washable or reusable?
No. They are single-use. Replace with a new filter each time.
2) Do I need the RP-404 tool?
It’s strongly recommended. The tool removes the barb safely without scratching the outlet.
3) Will these fit both G4 and G5?
Yes—RP-410 is used on Inogen One G4 & G5. Be sure you have the correct barb for your model.
4) How often should I replace the filter?
Monthly is standard. Replace sooner if you live with dust/pets or notice discoloration/restriction.
5) I hear a hiss at the outlet—what should I check?
Verify: (a) the RP-410 is fully seated, (b) the barb is snug and undamaged, and (c) your cannula is firmly attached. Replace worn parts.